Hotline:

Lenovo ThinkSystem PM1643a Entry - SSD

Lenovo ThinkSystem PM1643a Entry - SSD
Lenovo ThinkSystem PM1643a Entry - SSD
Manuf.No.:4XB7A17055
Art.No.:S23236130
Lenovo ThinkSystem PM1643a Entry, SSD, 7.68 TB, hot-swap, 2.5", SAS 12Gb/s, for ThinkAgile HX33XX Certified Node; MX3330-F Appliance; MX3331-F Certified Node
On request
Available
Delivery time approx. 1-3 days
Shopping cart
Description - Lenovo ThinkSystem PM1643a Entry - SSD
  • Enterprise-grade SSD suitable for read-intensive workloads
  • Based on Samsung 64-layer V-NAND technology and TLC flash memory
  • Endurance of 1 drive-write per day (DWPD) over 5 years
  • 2.5-inch or 3.5-inch industry standard form factor with hot-swap tray
  • SAS 12 Gbps interface
  • Single port host interface
  • Protect data integrity from unexpected power loss with Samsung's advanced power-loss protection architecture
  • Supports Self-Monitoring, Analysis and Reporting Technology (S.M.A.R.T)
  • End-to-end data protection
  • Support 16 Initiator with Tag Command Queuing (TCQ) Command Set with a queue-depth of up to 128 commands
  • Compliant with SCSI Specification (SAS-3 / SPL-3 / SBC-4 / SPC-4 / SAM-5)
The ThinkSystem PM1643a Entry SAS 12Gb solid-state drives (SSDs) are next-generation SSDs suitable for a wide range of applications. The PM1643a SAS SSDs are designed for dense storage and with a 12 Gb SAS interface, these drives feature all the capacity and performance that is needed to replace large numbers of 15K rpm and 10K rpm spinning disks, and consolidate storage into tightly packed server configurations.

Technical data - Lenovo ThinkSystem PM1643a Entry - SSD

General

Device Type Solid state drive - hot-swap
Capacity 7.68 TB
NAND Flash Memory Type Triple-level cell (TLC)
Form Factor 2.5"
Interface SAS 12Gb/s
Features Tagged Command Queuing (TCQ), End-to-end data protection, V-NAND Technology, power loss data protection, S.M.A.R.T.
Width 70 mm
Depth 100 mm
Height 15 mm
Weight 158 g

Performance

Drive Writes Per Day (DWPD) 1
SSD Endurance 14016 TB
Drive Transfer Rate 1.2 GBps (external)
Internal Data Rate 1000 MBps (read) / 1000 MBps (write)
4KB Random Read 230000 IOPS
4KB Random Write 90000 IOPS
Average Latency 220 µs

Reliability

MTBF 2,000,000 hours
Non-Recoverable Errors 1 per 10^17

Expansion & Connectivity

Interfaces 1 x SAS 12 Gb/s
Compatible Bay 2.5"

Power

Power Consumption 9 Watt (read)
12 Watt (write)

Miscellaneous

Compliant Standards UL, TUV, VCCI, C-Tick, BSMI, CB, IC, FCC, RoHS, KCC

Dimensions & Weight (Shipping)

Shipping Width 13.3 cm
Shipping Depth 17.4 cm
Shipping Height 6.3 cm

Manufacturer Warranty

Service & Support Limited warranty - replacement - 1 year

Environmental Parameters

Min Operating Temperature 0 °C
Max Operating Temperature 70 °C
Humidity Range Operating 5 - 95% (non-condensing)
Shock Tolerance (non-operating) 1500 g @ 0.5 ms
Vibration Tolerance (non-operating) 20 g @ 10-2000 Hz

Compatibility Information

Designed For Lenovo ThinkAgile HX1330 Appliance 7Z85 (2.5")
Lenovo ThinkAgile HX1331 Certified Node 7D52 (2.5")
Lenovo ThinkAgile HX2330 Appliance 7Z85 (2.5")
Lenovo ThinkAgile HX2331 Certified Node 7D52 (2.5")
Lenovo ThinkAgile HX3330 Appliance 7Z85 (2.5")
Lenovo ThinkAgile HX3331 Certified Node 7D52 (2.5")
Lenovo ThinkAgile HX3375 Appliance 7D5U (2.5")
Lenovo ThinkAgile HX3376 Certified Node 7D5U (2.5")
Lenovo ThinkAgile HX5530 Appliance 7Z82 (2.5")
Lenovo ThinkAgile HX5531 Certified Node 7Z84 (2.5")
Lenovo ThinkAgile HX7530 Appliance 7Z82 (2.5")
Lenovo ThinkAgile HX7531 Certified Node 7Z84 (2.5")
Lenovo ThinkAgile MX3330-F Appliance 7D19 (2.5")
Lenovo ThinkAgile MX3331-F Certified Node 7D67 (2.5")
Lenovo ThinkAgile VX Certified Node 7Y94 (2.5"), 7Z12 (2.5")
Lenovo ThinkAgile VX3320 Appliance 7Y93 (2.5")
Lenovo ThinkAgile VX3330 Appliance 7Z62 (2.5")
Lenovo ThinkAgile VX3331 7Z62 (2.5")
Lenovo ThinkAgile VX3530-G Appliance 7Z63 (2.5")
Lenovo ThinkAgile VX3575-G Integrated System 7D43 (2.5")
Lenovo ThinkAgile VX3720 Appliance 7Y92 (2.5")
Lenovo ThinkAgile VX5575 Integrated System 7D43 (2.5")
Lenovo ThinkAgile VX7520 Appliance 7Y94 (2.5")
Lenovo ThinkAgile VX7530 Appliance 7Z63 (2.5")
Lenovo ThinkAgile VX7531 Certified Node 7Z63 (2.5")
Lenovo ThinkAgile VX7575 Integrated System 7D43 (2.5")
Lenovo ThinkAgile VX7576 Certified Node 7D43 (2.5")
Lenovo ThinkAgile VX7820 Appliance 7Z13 (2.5")
Lenovo ThinkSystem SR530 7X08 (2.5")
Lenovo ThinkSystem SR570 7Y02 (2.5")
Lenovo ThinkSystem SR630 V2 7Z71 (2.5")
Lenovo ThinkSystem SR635 7Y98 (2.5"), 7Y99 (2.5")
Lenovo ThinkSystem SR650 V2 7D15 (2.5"), 7Z73 (2.5")
Lenovo ThinkSystem SR655 7Y00 (2.5"), 7Z01 (2.5")
Lenovo ThinkSystem SR665 7D2W (2.5")
Lenovo ThinkSystem SR850P 7D2F (2.5"), 7D2G (2.5"), 7D2H (2.5")
Lenovo ThinkSystem SR950 7X11 (2.5"), 7X12 (2.5"), 7X13 (2.5")
Lenovo ThinkSystem ST550 7X09 (2.5")

Lenovo

  • ThinkAgile HX1330 Appliance 7Z85 (When Server Storage Bays = hot-swap and Server Swappable Drive Form Factor = 2.5" and Server Swappable Drive Interface = SAS)
  • ThinkAgile HX1331 Certified Node 7D52 (When Server Storage Bays = hot-swap and Server Swappable Drive Form Factor = 2.5" and Server Swappable Drive Interface = SAS)
  • ThinkAgile HX2330 Appliance 7Z85 (When Server Storage Bays = hot-swap and Server Swappable Drive Form Factor = 2.5" and Server Swappable Drive Interface = SAS)
  • ThinkAgile HX2331 Certified Node 7D52 (When Server Storage Bays = hot-swap and Server Swappable Drive Form Factor = 2.5" and Server Swappable Drive Interface = SAS)
  • ThinkAgile HX3330 Appliance 7Z85 (When Server Storage Bays = hot-swap and Server Swappable Drive Form Factor = 2.5" and Server Swappable Drive Interface = SAS)
  • ThinkAgile HX3331 Certified Node 7D52 (When Server Storage Bays = hot-swap and Server Swappable Drive Form Factor = 2.5" and Server Swappable Drive Interface = SAS)
  • ThinkAgile HX3375 Appliance 7D5U (When Server Storage Bays = hot-swap and Server Swappable Drive Form Factor = 2.5" and Server Swappable Drive Interface = SAS)
  • ThinkAgile HX3376 Certified Node 7D5U (When Server Storage Bays = hot-swap and Server Swappable Drive Form Factor = 2.5" and Server Swappable Drive Interface = SAS)
  • ThinkAgile HX5530 Appliance 7Z82 (When Server Storage Bays = hot-swap and Server Swappable Drive Form Factor = 2.5" and Server Swappable Drive Interface = SAS)
  • ThinkAgile HX5531 Certified Node 7Z84 (When Server Storage Bays = hot-swap and Server Swappable Drive Form Factor = 2.5" and Server Swappable Drive Interface = SAS)
  • ThinkAgile HX7530 Appliance 7Z82 (When Server Storage Bays = hot-swap and Server Swappable Drive Form Factor = 2.5" and Server Swappable Drive Interface = SAS)
  • ThinkAgile HX7531 Certified Node 7Z84 (When Server Storage Bays = hot-swap and Server Swappable Drive Form Factor = 2.5" and Server Swappable Drive Interface = SAS)
  • ThinkAgile MX3330-F Appliance 7D19 (When Server Storage Bays = hot-swap and Server Swappable Drive Form Factor = 2.5" and Server Swappable Drive Interface = SAS)
  • ThinkAgile MX3331-F Certified Node 7D67 (When Server Storage Bays = hot-swap and Server Swappable Drive Form Factor = 2.5" and Server Swappable Drive Interface = SAS)
  • ThinkAgile VX Certified Node 7Y94 (When Server Storage Bays = hot-swap and Server Swappable Drive Form Factor = 2.5" and Server Swappable Drive Interface = SAS)
  • ThinkAgile VX Certified Node 7Z12 (When Server Storage Bays = hot-swap and Server Swappable Drive Form Factor = 2.5" and Server Swappable Drive Interface = SAS)
  • ThinkAgile VX3320 Appliance 7Y93 (When Server Storage Bays = hot-swap and Server Swappable Drive Form Factor = 2.5" and Server Swappable Drive Interface = SAS)
  • ThinkAgile VX3330 Appliance 7Z62 (When Server Storage Bays = hot-swap and Server Swappable Drive Form Factor = 2.5" and Server Swappable Drive Interface = SAS)
  • ThinkAgile VX3331 7Z62 (When Server Storage Bays = hot-swap and Server Swappable Drive Form Factor = 2.5" and Server Swappable Drive Interface = SAS)
  • ThinkAgile VX3530-G Appliance 7Z63 (When Server Storage Bays = hot-swap and Server Swappable Drive Form Factor = 2.5" and Server Swappable Drive Interface = SAS)
  • ThinkAgile VX3575-G Integrated System 7D43 (When Server Storage Bays = hot-swap and Server Swappable Drive Form Factor = 2.5" and Server Swappable Drive Interface = SAS)
  • ThinkAgile VX3720 Appliance 7Y92 (When Server Storage Bays = hot-swap and Server Swappable Drive Form Factor = 2.5" and Server Swappable Drive Interface = SAS)
  • ThinkAgile VX5575 Integrated System 7D43 (When Server Storage Bays = hot-swap and Server Swappable Drive Form Factor = 2.5" and Server Swappable Drive Interface = SAS)
  • ThinkAgile VX7520 Appliance 7Y94 (When Server Storage Bays = hot-swap and Server Swappable Drive Form Factor = 2.5" and Server Swappable Drive Interface = SAS)
  • ThinkAgile VX7530 Appliance 7Z63 (When Server Storage Bays = hot-swap and Server Swappable Drive Form Factor = 2.5" and Server Swappable Drive Interface = SAS)
  • ThinkAgile VX7531 Certified Node 7Z63 (When Server Storage Bays = hot-swap and Server Swappable Drive Form Factor = 2.5" and Server Swappable Drive Interface = SAS)
  • ThinkAgile VX7575 Integrated System 7D43 (When Server Storage Bays = hot-swap and Server Swappable Drive Form Factor = 2.5" and Server Swappable Drive Interface = SAS)
  • ThinkAgile VX7576 Certified Node 7D43 (When Server Storage Bays = hot-swap and Server Swappable Drive Form Factor = 2.5" and Server Swappable Drive Interface = SAS)
  • ThinkAgile VX7820 Appliance 7Z13 (When Server Storage Bays = hot-swap and Server Swappable Drive Form Factor = 2.5" and Server Swappable Drive Interface = SAS)
  • ThinkSystem SD530 7X21 (When Server Storage Bays = hot-swap and Server Swappable Drive Form Factor = 2.5" and Server Swappable Drive Interface = SAS)
  • ThinkSystem SN550 7X16 (When Server Storage Bays = hot-swap and Server Swappable Drive Form Factor = 2.5" and Server Swappable Drive Interface = SAS)
  • ThinkSystem SN850 7X15 (When Server Storage Bays = hot-swap and Server Swappable Drive Form Factor = 2.5" and Server Swappable Drive Interface = SAS)
  • ThinkSystem SR530 7X07 (When Server Storage Bays = hot-swap and Server Swappable Drive Form Factor = 2.5" and Server Swappable Drive Interface = SAS)
  • ThinkSystem SR530 7X08 (When Server Storage Bays = hot-swap and Server Swappable Drive Form Factor = 2.5" and Server Swappable Drive Interface = SAS)
  • ThinkSystem SR550 7X03 (When Server Storage Bays = hot-swap and Server Swappable Drive Form Factor = 2.5" and Server Swappable Drive Interface = SAS)
  • ThinkSystem SR550 7X04 (When Server Storage Bays = hot-swap and Server Swappable Drive Form Factor = 2.5" and Server Swappable Drive Interface = SAS)
  • ThinkSystem SR570 7Y02 (When Server Storage Bays = hot-swap and Server Swappable Drive Form Factor = 2.5" and Server Swappable Drive Interface = SAS)
  • ThinkSystem SR570 7Y03 (When Server Storage Bays = hot-swap and Server Swappable Drive Form Factor = 2.5" and Server Swappable Drive Interface = SAS)
  • ThinkSystem SR570 7Y04 (When Server Storage Bays = hot-swap and Server Swappable Drive Form Factor = 2.5" and Server Swappable Drive Interface = SAS)
  • ThinkSystem SR590 7X98 (When Server Storage Bays = hot-swap and Server Swappable Drive Form Factor = 2.5" and Server Swappable Drive Interface = SAS)
  • ThinkSystem SR590 7X99 (When Server Storage Bays = hot-swap and Server Swappable Drive Form Factor = 2.5" and Server Swappable Drive Interface = SAS)
  • ThinkSystem SR630 7X01 (When Server Storage Bays = hot-swap and Server Swappable Drive Form Factor = 2.5" and Server Swappable Drive Interface = SAS)
  • ThinkSystem SR630 7X02 (When Server Storage Bays = hot-swap and Server Swappable Drive Form Factor = 2.5" and Server Swappable Drive Interface = SAS)
  • ThinkSystem SR630 V2 7Z71 (When Server Storage Bays = hot-swap and Server Swappable Drive Form Factor = 2.5" and Server Swappable Drive Interface = SAS)
  • ThinkSystem SR635 7Y98 (When Server Storage Bays = hot-swap and Server Swappable Drive Form Factor = 2.5" and Server Swappable Drive Interface = SAS)
  • ThinkSystem SR635 7Y99 (When Server Storage Bays = hot-swap and Server Swappable Drive Form Factor = 2.5" and Server Swappable Drive Interface = SAS)
  • ThinkSystem SR650 7X05 (When Server Storage Bays = hot-swap and Server Swappable Drive Form Factor = 2.5" and Server Swappable Drive Interface = SAS)
  • ThinkSystem SR650 7X06 (When Server Storage Bays = hot-swap and Server Swappable Drive Form Factor = 2.5" and Server Swappable Drive Interface = SAS)
  • ThinkSystem SR650 V2 7D15 (When Server Storage Bays = hot-swap and Server Swappable Drive Form Factor = 2.5" and Server Swappable Drive Interface = SAS)
  • ThinkSystem SR650 V2 7Z73 (When Server Storage Bays = hot-swap and Server Swappable Drive Form Factor = 2.5" and Server Swappable Drive Interface = SAS)
  • ThinkSystem SR655 7Y00 (When Server Storage Bays = hot-swap and Server Swappable Drive Form Factor = 2.5" and Server Swappable Drive Interface = SAS)
  • ThinkSystem SR655 7Z01 (When Server Storage Bays = hot-swap and Server Swappable Drive Form Factor = 2.5" and Server Swappable Drive Interface = SAS)
  • ThinkSystem SR665 7D2W (When Server Storage Bays = hot-swap and Server Swappable Drive Form Factor = 2.5" and Server Swappable Drive Interface = SAS)
  • ThinkSystem SR850 7X18 (When Server Storage Bays = hot-swap and Server Swappable Drive Form Factor = 2.5" and Server Swappable Drive Interface = SAS)
  • ThinkSystem SR850 7X19 (When Server Storage Bays = hot-swap and Server Swappable Drive Form Factor = 2.5" and Server Swappable Drive Interface = SAS)
  • ThinkSystem SR850P 7D2F (When Server Storage Bays = hot-swap and Server Swappable Drive Form Factor = 2.5" and Server Swappable Drive Interface = SAS)
  • ThinkSystem SR850P 7D2G (When Server Storage Bays = hot-swap and Server Swappable Drive Form Factor = 2.5" and Server Swappable Drive Interface = SAS)
  • ThinkSystem SR850P 7D2H (When Server Storage Bays = hot-swap and Server Swappable Drive Form Factor = 2.5" and Server Swappable Drive Interface = SAS)
  • ThinkSystem SR860 7X69 (When Server Storage Bays = hot-swap and Server Swappable Drive Form Factor = 2.5" and Server Swappable Drive Interface = SAS)
  • ThinkSystem SR860 7X70 (When Server Storage Bays = hot-swap and Server Swappable Drive Form Factor = 2.5" and Server Swappable Drive Interface = SAS)
  • ThinkSystem SR950 7X11 (When Server Storage Bays = hot-swap and Server Swappable Drive Form Factor = 2.5" and Server Swappable Drive Interface = SAS)
  • ThinkSystem SR950 7X12 (When Server Storage Bays = hot-swap and Server Swappable Drive Form Factor = 2.5" and Server Swappable Drive Interface = SAS)
  • ThinkSystem SR950 7X13 (When Server Storage Bays = hot-swap and Server Swappable Drive Form Factor = 2.5" and Server Swappable Drive Interface = SAS)
  • ThinkSystem ST550 7X09 (When Server Storage Bays = hot-swap and Server Swappable Drive Form Factor = 2.5" and Server Swappable Drive Interface = SAS)
  • ThinkSystem ST550 7X10 (When Server Storage Bays = hot-swap and Server Swappable Drive Form Factor = 2.5" and Server Swappable Drive Interface = SAS)
  • Languages available:
  • Languages available:
Please keep in mind that this shop is restricted to business clients.
All prices quoted are subject to VAT.
Ultrabook, Celeron, Celeron Inside, Core Inside, Intel, Intel Logo, Intel Atom, Intel Atom Inside, Intel Core, Intel Inside, Intel Inside Logo, Intel vPro, Itanium, Itanium Inside, Pentium, Pentium Inside, vPro Inside, Xeon, Xeon Phi, and Xeon Inside are trademarks of the Intel Corporation or its subsidiaries in the USA or other countries.
Graphics and technical data can differ from the original.The product description is decisive for the scope of goods.